Mitsubishi Electric hyper-heating air conditioning systems deliver excellent heating performance under extremely low outdoor temperatures.
Breakthrough air conditioning heating performance Mitsubishi Electric introduces a breakthrough in air conditioning heating performance with the introduction of a hyper-heating series. Unlike conventional air conditioning systems, the MSZ-FB VAH does not loose heating capacity when it is cold outside.
A Mitsubishi Electric hyper-heating Heat Pump will deliver the same amount of heat whether operating at 7°C or –15°C.

The Mitsubishi Electric hyper-heating Heat Pump Range is fitted with an advanced compressor that allows superior heating performance, even in sub zero temperatures. The key to its superior performance is the Mitsubishi Electric “Heat Caulking” compressor technology that allows larger amounts of refrigerant to be moved around the system using less energy.
i-see sensor
For the ultimate in clean air conditioning, Mitsubishi Electric has created the deluxe inverter split system. These models feature the unique moving i-See Sensor, one of the most advanced temperature sensors on the market. The i-See Sensor constantly scans the floor level temperature seeking out hot or cold spots and automatically directs the airflow to correct the temperature.
PlasmaDuo filter systems
The units also see the introduction of the Plasma Duo Filter System, which improves air quality and removes chemical substances from the atmosphere of a home. Mitsubishi Electric has also continued its application of sleek design, recognising that air conditioning units should be unobtrusive and visually pleasing in the domestic environment.
Model Name | MSZ-FB35VAH | MSZ-FB50VAH | MSZ-FB50VAH | |||
Type | Inverter | Inverter | Inverter | |||
Indoor Unit | MSZ-FB35VA | MSZ-FB50VA | MSZ-FB50VA | |||
Outdoor Unit | MUZ-FB25VAH | MUZ-FB35VAH | MUFZ-FB50VAH | |||
System Name | ||||||
Cooling | ||||||
Capacity (Rated Conditions) kW | 3.5 | 5 | 4.8 | |||
Capacity (Min - Max) kW | 0.8 - 4.1 | 0.8 - 5.8 | 0.9 - 5.4 | |||
Air Flow (Low - Shi) l/s | 77 - 187 | 105 - 247 | 118 - 221 | |||
EER (Rated Conditions) | 3.93 | 3.66 | 3.1 | |||
Star Rating - Original calculation | 6 | 5 | 4.5 | |||
Star Rating - New calculation | TBA | TBA | TBA | |||
Sound Pressure Levels | ||||||
Indoor at 1.5m (Low/Med/Hi/SHi) dBA | 20-29-36-43 | 29-39-45-52 | 32-37-43-48 | |||
Outdoor at 1m dBA | 47 | 54 | 54 | |||
Sound Power Level - Outdoor dBA | ||||||
Heating | ||||||
Capacity (Rated Conditions) kW | 4 | 6 | 5.4 | |||
Capacity (Min - Max) kW | 1.3 - 6.5 | 0.9 - 8.2 | 0.9 - 7.9 | |||
Air Flow (Low/Shi) l/s | 78 - 208 | 92 - 247 | 123 - 227 | |||
COP (Rated Conditions) | 4.44 | 3.66 | 3.42 | |||
Star Rating - Original calculation | 6 | 5.5 | 5 | |||
Star Rating - New calculation | ||||||
Sound Pressure Levels | ||||||
Indoor at 1.5m (Low/Med/Hi/SHi) dBA | 21-29-36-44 | 27-37-43-50 | 32-37-43-49 | |||
Outdoor at 1m dBA | 50 | 56 | 56 | |||
Sound Power Level - Outdoor dBA | ||||||
Indoor - Dimensions (HxWxD) mm | 295x798x257 | 295x798x257 | 600x700x200 | |||
Weight - Indoor kg | 12 | 12 | 14 | |||
Outdoor - Dimensions (HxWxD) mm | 550x800x285 | 850x840x285 | 850x840x330 | |||
Weight - Outdoor kg | 36 | 55 | 55 | |||
Electrical Supply | 240volt/Single Phase/ 50 Hertz - Outdoor Power Supply | |||||
Breaker Size A | 10.5 | 16 | 16 | |||
Piping - max length m | 20 | 30 | 30 | |||
max height m | 12 | 15 | 15 | |||
Guaranteed Operating Range - Cooling °C | -10 - 46 | -10 - 46 | -10 - 46 | |||
Guaranteed Operating Range - Heating °C | -25 - 24 | -25 - 24 | -25 - 24 |