MSZ-FB Series - 2.5 kW - 5.0 kW
The MSZ-FB Series "F-Inverter" split system air conditioner combines 6 star energy efficiency, quiet operation and advanced air filtration for the ultimate in room comfort.
i-see Sensor

For the ultimate in clean air conditioning, Mitsubishi Electric has created the deluxe inverter split system. These models feature the unique moving i-See Sensor, one of the most advanced temperature sensors on the market. The i-See Sensor constantly scans the floor level temperature seeking out hot or cold spots and automatically directs the airflow to correct the temperature.
PlasmaDuo Filter System
The units also see the introduction of the Plasma Duo Filter System, which improves air quality and removes chemical substances from the atmosphere of a home. Mitsubishi Electric has also continued its application of sleek design, recognising that air conditioning units should be unobtrusive and visually pleasing in the domestic environment.
High Energy Efficiency
With the latest inverter technology, energy efficiency is improved by about 13% in cooling operation and heating operation from the "FA" (25 class). This contributes to further reduction in product power consumption
Other features include:
- Auto Front Panel - opens and closes when the unit is turned on and off. When closed it provides a smart and sleek visual appearance.
- Area Setting - set the target area to improve energy efficiency – heat or cool the whole room, or just one side.
- Quick clean design - the front panel is easily detached and the air flow vents can be opened without special tools, making cleaning a breeze.
- Quiet operation - some models operate as quietly as 20 dB(A).
- Mold Fighter - ozone generated to supress to growth of mold on the indoor unit
Model Name | MSZ-FB25VA | MSZ-FB35VA | MSZ-FB50VA | |||
Type | Inverter | Inverter | Inverter | |||
Indoor Unit | MSZ-FB25VA | MSZ-FB35VA | MSZ-FB50VA | |||
Outdoor Unit | MUZ-FB25VA | MUZ-FB35VA | MUZ-FB50VA | |||
System Name | MSZFB25KIT | MSZFB35KIT | MSZFB50KIT | |||
Cooling | ||||||
Capacity (Rated Conditions) kW | 2.5 | 3.5 | 5 | |||
Capacity (Min - Max) kW | 1.1 - 3.5 | 1.1 - 4.1 | 0.9 - 5.8 | |||
Air Flow (Low - Shi) l/s | 77 - 187 | 77 - 187 | 105 - 247 | |||
EER (Rated Conditions) | 4.81 | 3.93 | 3.13 | |||
Star Rating - Original calculation | 6 | 6 | 5 | |||
Star Rating - New calculation | 4.5 | 3 | 1.5 | |||
Sound Pressure Levels | ||||||
Indoor at 1.5m (Low/Med/Hi/SHi) dBA | 20-29-36-43 | 20-29-36-43 | 29-39-45-52 | |||
Outdoor at 1m dBA | 46 | 47 | 54 | |||
Sound Power Level - Outdoor dBA | 59 | 60 | 67 | |||
Heating | ||||||
Capacity (Rated Conditions) kW | 3.2 | 4 | 6 | |||
Capacity (Min - Max) kW | 1.5 - 5.5 | 1.5 - 6 | 0.9 - 7.8 | |||
Air Flow (Low/Med/Hi/Shi) l/s | 75 - 202 | 78 - 208 | 92 - 247 | |||
COP (Rated Conditions) | 4.92 | 4.44 | 3.66 | |||
Star Rating - Original calculation | 6 | 6 | 5.5 | |||
Star Rating - New calculation | 5 | 4 | 2.5 | |||
Sound Pressure Levels | ||||||
Indoor at 1.5m (Low/Med/Hi/SHi) dBA | 20-29-36-43 | 20-29-36-43 | 27-37-43-50 | |||
Outdoor at 1m dBA | 46 | 50 | 56 | |||
Sound Power Level - Outdoor dBA | 59 | 63 | 69 | |||
Indoor - Dimensions (HxWxD) mm | 295x798x257 | 295x798x257 | 295x798x257 | |||
Weight - Indoor kg | 12 | 12 | 12 | |||
Outdoor - Dimensions (HxWxD) mm | 550x800x285 | 550x800x285 | 850x840x330 | |||
Weight - Outdoor kg | 36 | 36 | 55 | |||
Electrical Supply | 240volt/Single Phase/ 50 Hertz - Outdoor Power Supply | |||||
Breaker Size A | 10 | 10 | 16 | |||
Piping - max length m | 20 | 20 | 30 | |||
max height m | 12 | 12 | 15 | |||
Guaranteed Operating Range - Cooling °C | -10 - 46 | -10 - 46 | -10 - 46 | |||
Guaranteed Operating Range - Heating °C | -15 - 24 | -15 - 24 | -15 - 24 |